Technical Files for MDR 2017/745 & IVDR 2017/746
Preparing and maintaining complete technical documentation for CE marking.
EUmAccess GmbH provides expert consultancy to help manufacturers prepare and maintain Technical Files in compliance with EU MDR 2017/745 (medical devices) and IVDR 2017/746 (in vitro diagnostic devices).
Proper technical documentation is essential for CE marking, regulatory approvals and market access in the European Union.
What is a Technical File?
A Technical File (technical documentation) is a legally required set of documents that demonstrates a device's safety, performance and compliance with the relevant EU regulations. It must be maintained throughout the device lifecycle and updated when necessary.
- Required for all classes of medical devices and IVDs
- Essential for CE marking and conformity assessment
- Reviewed by Notified Bodies (for higher-risk devices)
- Must be available to Competent Authorities upon request
Technical File requirements under MDR and IVDR
A complete Technical File includes the following sections:
Device description and specifications
- General product description
- Intended purpose and indications for use
- Device classification (MDR Annex VIII, IVDR Annex VIII)
- Unique Device Identification (UDI) system
Design and manufacturing information
- Design specifications and drawings
- Manufacturing process details
- List of all materials and components used
GSPR compliance
- Demonstration of compliance with Annex I of MDR or IVDR
- Risk-benefit analysis and justification
- Verification and validation testing
Risk management (ISO 14971:2019)
- Risk analysis, evaluation and control measures
- Risk-benefit assessment
- Post-market risk monitoring
Clinical evaluation (MDR) / performance evaluation (IVDR)
- MDR: Clinical Evaluation Report (CER) in compliance with Annex XIV
- IVDR: Performance Evaluation Report (PER) covering scientific validity, analytical and clinical performance
Pre-clinical testing and biocompatibility
- Biocompatibility (ISO 10993)
- Electrical safety and electromagnetic compatibility (IEC 60601)
- Sterilisation validation (ISO 11135, ISO 17665, ISO 11737)
Software and cybersecurity (if applicable)
- Software lifecycle documentation (IEC 62304)
- Cybersecurity risk assessment
- Artificial intelligence (AI) validation, if applicable
Labelling and instructions for use (IFU)
- Device labelling requirements (UDI, language and symbols)
- IFU compliant with MDR / IVDR
- Packaging information
Post-market surveillance and vigilance
- PMS Plan and Periodic Safety Update Report (PSUR)
- Post-Market Clinical Follow-up (PMCF)
- Incident and field safety corrective action (FSCA) procedures
EUDAMED registration and Declaration of Conformity
- Manufacturer and device registration in EUDAMED
- Declaration of Conformity (DoC) as per Annex IV
Who needs a Technical File?
- Medical device and IVD manufacturers (EU and non-EU)
- Non-EU manufacturers, who must appoint an EU Authorised Representative
- Importers and distributors, who must verify compliance before placing devices on the market
Our Technical File consultancy services
File creation
- Assisting in the creation of complete, MDR / IVDR-compliant documentation
- Identifying the correct risk classification
- Determining the appropriate conformity assessment route
Gap analysis and compliance audit
- Reviewing existing files for missing or outdated documents
Work flow for this service
Every engagement follows the same documented work flow (EUM-F-062), from your first enquiry to the closing review.
- Client communication by e-mail, LinkedIn or through our collaborators
- Enquiry
- Application form shared and received (open the form)
- Contract review
- Quotation prepared and sent; revised or closed if not accepted
- Proforma invoice and draft agreement sent
- Payment received; invoice and final agreement sent
- Client coordination by e-mail and WhatsApp
Our consultants prepare, review and deliver the agreed documents and systems.
- Internal feedback
- External feedback
- Complaint handling
- Non-conformity reporting
- Review meeting
- Continuous improvement actions
- End of the engagement
Related services
Technical File (TF) Review
Gap analysis and Notified Body-ready review of your technical documentation.
Know moreClinical Evaluation: CER, PMS, PMCF, PSUR, SSCP
Clinical evidence and post-market documentation for MDR and IVDR.
Know moreRisk Assessment – ISO 14971:2019
ISO 14971-compliant risk management across the device lifecycle.
Know moreReady to enter the European market?
Tell us about your devices and target countries. We will come back with the scope of your mandate.