EU Authorised Representative in Mannheim, GermanyEUDAMED Actor-ID DE-AR-000044845
+49 621-76-44-10-101contact@eumaccess.com
Home/Regulatory & QMS Consultancy/IVDR | Regulation (EU) 2017/746

CE Marking under IVDR | Regulation (EU) 2017/746

CE marking consultancy for in vitro diagnostic devices, Class A to D.

EUmAccess GmbH provides expert CE marking consultancy to help in vitro diagnostic (IVD) manufacturers comply with Regulation (EU) 2017/746 (IVDR) and achieve seamless market access in the European Union.

What is CE marking for IVDs under IVDR?

CE marking under IVDR is a mandatory certification confirming that an IVD device meets EU safety, performance and regulatory requirements. It is essential for selling IVDs in the EEA.

  • Required for all in vitro diagnostic devices (Class A, B, C, D)
  • Ensures compliance with IVDR 2017/746
  • Confirms safety, accuracy and performance of IVD devices
  • Mandatory for market access in the EU

Key changes in IVDR compared to IVDD

  • Stricter classification rulesNew risk-based A to D classification system
  • More involvement of Notified BodiesMost IVDs now require Notified Body certification
  • Stronger clinical evidence requirementsMore emphasis on clinical performance and risk assessment
  • Enhanced post-market surveillanceStronger obligations for manufacturers and economic operators
  • Mandatory EUDAMED registrationAll devices and manufacturers must be registered in EUDAMED

Our CE marking consultancy services for IVDR

IVD classification and regulatory strategy

  • Identifying the correct IVDR risk class (Class A, B, C, D)
  • Determining the appropriate conformity assessment route

Technical documentation and performance evaluation

  • Preparing IVDR-compliant Technical Files and Performance Evaluation Reports (PER)
  • Ensuring compliance with Annex II and III of IVDR 2017/746

EU Authorised Representative services

  • Acting as your official EU Representative for regulatory compliance
  • Managing EUDAMED registration and post-market surveillance (PMS)

Notified Body selection and certification support

  • Assisting in selecting a Notified Body (Class B, C, D devices)
  • Supporting the audit, conformity assessment and certification process

Risk management and post-market surveillance

  • Implementing ISO 14971:2019 risk management requirements
  • Developing PMS and vigilance plans

CE marking training and compliance consulting

  • Expert training and workshops on IVDR requirements

The CE marking process under IVDR 2017/746

The steps are the same for every IVD, but the Notified Body involvement and the conformity assessment route depend on the class. Find your class in the top row and read down.

StepClass Anon-sterileClass A sterileClass BClass CClass Dhighest risk
1. ClassificationDetermine the class using the rules in Annex VIII of the IVDR●Required●Required●Required●Required●Required
2. Quality management systemImplement a QMS in accordance with IVDR; most companies apply ISO 13485●Required●Required●Required●Required●Required
3. Technical fileTechnical documentation per Annex II and III●Required●Required●Required●Required●Required
4. Performance evaluationScientific validity, analytical performance and clinical performance●Required●Required●Required●Required●Required
5. Authorised RepresentativeNon-EU manufacturers appoint an EC REP; name and address go on the packaging●Required●Required●Required●Required●Required
6. EUDAMED registrationRegister manufacturer and device; assign the UDI●Required●Required●Required●Required●Required
7. Notified Body audit of the QMSAudit by an EU-designated Notified BodyNot requiredLimited to the sterility aspects●Required●Required●Required
8. Notified Body review of the technical fileTechnical documentation assessmentNot requiredLimited to the sterility aspectsSampled: one representative device per device categorySampled: one per generic device groupEvery device
9. Additional scrutinyExtra steps for specific device typesNot requiredNot requiredSelf-tests and near-patient tests: file assessed for each deviceCompanion diagnostics: consultation with a medicines authorityEU reference laboratory verification and batch testing; expert panel view where no common specifications exist
10. CE certificateIssued by the Notified Body after a successful auditNot required●Required●Required●Required●Required
11. Declaration of Conformity and CE markingLegally binding declaration by the manufacturerSelf-declared; CE mark without Notified Body numberCE mark with Notified Body numberCE mark with Notified Body numberCE mark with Notified Body numberCE mark with Notified Body number
12. Post-market surveillanceOngoing reporting after market placementPMS reportPMS reportPMS reportPSUR at least every year; SSPPSUR at least every year; SSP

● Required for this class Not required Step does not apply

  • A Notified Body is an EU-designated third party authorised to audit IVD companies and their devices.
  • A CE certificate issued by a Notified Body does not apply to Class A non-sterile devices: the manufacturer self-declares conformity with Regulation (EU) 2017/746.
  • SSP: Summary of Safety and Performance, published in EUDAMED for Class C and D devices.

Conformity assessment route by class (IVDR Article 48)

ClassRouteNotified Body
Class ADeclaration of Conformity based on the technical documentation of Annex II and III (Art. 48(10))None
Class A sterileAs Class A, plus Annex IX or Annex XI limited to the sterility aspects (Art. 48(10))Limited scope
Class BAnnex IX Chapters I and III with assessment of the technical documentation of at least one representative device per device category (Art. 48(9))Yes
Class CAnnex IX Chapters I and III with assessment of the technical documentation of at least one representative device per generic device group; or Annex X type-examination with Annex XI (Art. 48(7) and (8))Yes
Class DAnnex IX Chapters I, II and III with assessment of every device; or Annex X type-examination with Annex XI (Art. 48(3) and (4))Yes

This is a summary for orientation. The route for your device also depends on its classification rule and the special cases in Article 48. We confirm it with you during classification.

Who needs CE marking under IVDR?

  • IVD manufacturers (EU and non-EU)
  • Non-EU manufacturers, who must appoint an EU Authorised Representative
  • Distributors and importers, who must verify device compliance

Work flow for this service

Every engagement follows the same documented work flow (EUM-F-062), from your first enquiry to the closing review.

1Planning phase
  1. Client communication by e-mail, LinkedIn or through our collaborators
  2. Enquiry
  3. Application form shared and received (open the form)
  4. Contract review
  5. Quotation prepared and sent; revised or closed if not accepted
  6. Proforma invoice and draft agreement sent
  7. Payment received; invoice and final agreement sent
  8. Client coordination by e-mail and WhatsApp
2Execution phase
Consultancy: IVDR | Regulation (EU) 2017/746

Our consultants prepare, review and deliver the agreed documents and systems.

EUDAMED registrationAuthorised representationTrainingAuditsConsultancy
3Reporting phase
  1. Internal feedback
  2. External feedback
  3. Complaint handling
  4. Non-conformity reporting
4Closing phase
  1. Review meeting
  2. Continuous improvement actions
  3. End of the engagement

Ready to enter the European market?

Tell us about your devices and target countries. We will come back with the scope of your mandate.