CE Marking under IVDR | Regulation (EU) 2017/746
CE marking consultancy for in vitro diagnostic devices, Class A to D.
EUmAccess GmbH provides expert CE marking consultancy to help in vitro diagnostic (IVD) manufacturers comply with Regulation (EU) 2017/746 (IVDR) and achieve seamless market access in the European Union.
What is CE marking for IVDs under IVDR?
CE marking under IVDR is a mandatory certification confirming that an IVD device meets EU safety, performance and regulatory requirements. It is essential for selling IVDs in the EEA.
- Required for all in vitro diagnostic devices (Class A, B, C, D)
- Ensures compliance with IVDR 2017/746
- Confirms safety, accuracy and performance of IVD devices
- Mandatory for market access in the EU
Key changes in IVDR compared to IVDD
- Stricter classification rulesNew risk-based A to D classification system
- More involvement of Notified BodiesMost IVDs now require Notified Body certification
- Stronger clinical evidence requirementsMore emphasis on clinical performance and risk assessment
- Enhanced post-market surveillanceStronger obligations for manufacturers and economic operators
- Mandatory EUDAMED registrationAll devices and manufacturers must be registered in EUDAMED
Our CE marking consultancy services for IVDR
IVD classification and regulatory strategy
- Identifying the correct IVDR risk class (Class A, B, C, D)
- Determining the appropriate conformity assessment route
Technical documentation and performance evaluation
- Preparing IVDR-compliant Technical Files and Performance Evaluation Reports (PER)
- Ensuring compliance with Annex II and III of IVDR 2017/746
EU Authorised Representative services
- Acting as your official EU Representative for regulatory compliance
- Managing EUDAMED registration and post-market surveillance (PMS)
Notified Body selection and certification support
- Assisting in selecting a Notified Body (Class B, C, D devices)
- Supporting the audit, conformity assessment and certification process
Risk management and post-market surveillance
- Implementing ISO 14971:2019 risk management requirements
- Developing PMS and vigilance plans
CE marking training and compliance consulting
- Expert training and workshops on IVDR requirements
The CE marking process under IVDR 2017/746
The steps are the same for every IVD, but the Notified Body involvement and the conformity assessment route depend on the class. Find your class in the top row and read down.
| Step | Class Anon-sterile | Class A sterile | Class B | Class C | Class Dhighest risk |
|---|---|---|---|---|---|
| 1. ClassificationDetermine the class using the rules in Annex VIII of the IVDR | ●Required | ●Required | ●Required | ●Required | ●Required |
| 2. Quality management systemImplement a QMS in accordance with IVDR; most companies apply ISO 13485 | ●Required | ●Required | ●Required | ●Required | ●Required |
| 3. Technical fileTechnical documentation per Annex II and III | ●Required | ●Required | ●Required | ●Required | ●Required |
| 4. Performance evaluationScientific validity, analytical performance and clinical performance | ●Required | ●Required | ●Required | ●Required | ●Required |
| 5. Authorised RepresentativeNon-EU manufacturers appoint an EC REP; name and address go on the packaging | ●Required | ●Required | ●Required | ●Required | ●Required |
| 6. EUDAMED registrationRegister manufacturer and device; assign the UDI | ●Required | ●Required | ●Required | ●Required | ●Required |
| 7. Notified Body audit of the QMSAudit by an EU-designated Notified Body | Not required | Limited to the sterility aspects | ●Required | ●Required | ●Required |
| 8. Notified Body review of the technical fileTechnical documentation assessment | Not required | Limited to the sterility aspects | Sampled: one representative device per device category | Sampled: one per generic device group | Every device |
| 9. Additional scrutinyExtra steps for specific device types | Not required | Not required | Self-tests and near-patient tests: file assessed for each device | Companion diagnostics: consultation with a medicines authority | EU reference laboratory verification and batch testing; expert panel view where no common specifications exist |
| 10. CE certificateIssued by the Notified Body after a successful audit | Not required | ●Required | ●Required | ●Required | ●Required |
| 11. Declaration of Conformity and CE markingLegally binding declaration by the manufacturer | Self-declared; CE mark without Notified Body number | CE mark with Notified Body number | CE mark with Notified Body number | CE mark with Notified Body number | CE mark with Notified Body number |
| 12. Post-market surveillanceOngoing reporting after market placement | PMS report | PMS report | PMS report | PSUR at least every year; SSP | PSUR at least every year; SSP |
● Required for this class Not required Step does not apply
- A Notified Body is an EU-designated third party authorised to audit IVD companies and their devices.
- A CE certificate issued by a Notified Body does not apply to Class A non-sterile devices: the manufacturer self-declares conformity with Regulation (EU) 2017/746.
- SSP: Summary of Safety and Performance, published in EUDAMED for Class C and D devices.
Conformity assessment route by class (IVDR Article 48)
| Class | Route | Notified Body |
|---|---|---|
| Class A | Declaration of Conformity based on the technical documentation of Annex II and III (Art. 48(10)) | None |
| Class A sterile | As Class A, plus Annex IX or Annex XI limited to the sterility aspects (Art. 48(10)) | Limited scope |
| Class B | Annex IX Chapters I and III with assessment of the technical documentation of at least one representative device per device category (Art. 48(9)) | Yes |
| Class C | Annex IX Chapters I and III with assessment of the technical documentation of at least one representative device per generic device group; or Annex X type-examination with Annex XI (Art. 48(7) and (8)) | Yes |
| Class D | Annex IX Chapters I, II and III with assessment of every device; or Annex X type-examination with Annex XI (Art. 48(3) and (4)) | Yes |
This is a summary for orientation. The route for your device also depends on its classification rule and the special cases in Article 48. We confirm it with you during classification.
Who needs CE marking under IVDR?
- IVD manufacturers (EU and non-EU)
- Non-EU manufacturers, who must appoint an EU Authorised Representative
- Distributors and importers, who must verify device compliance
Work flow for this service
Every engagement follows the same documented work flow (EUM-F-062), from your first enquiry to the closing review.
- Client communication by e-mail, LinkedIn or through our collaborators
- Enquiry
- Application form shared and received (open the form)
- Contract review
- Quotation prepared and sent; revised or closed if not accepted
- Proforma invoice and draft agreement sent
- Payment received; invoice and final agreement sent
- Client coordination by e-mail and WhatsApp
Our consultants prepare, review and deliver the agreed documents and systems.
- Internal feedback
- External feedback
- Complaint handling
- Non-conformity reporting
- Review meeting
- Continuous improvement actions
- End of the engagement
Ready to enter the European market?
Tell us about your devices and target countries. We will come back with the scope of your mandate.