Home/Regulatory & QMS Consultancy/MDR | Regulation (EU) 2017/745

CE Marking under MDR | Regulation (EU) 2017/745

CE marking consultancy for medical devices of every class.

EUmAccess GmbH provides expert CE marking consultancy to help medical device manufacturers comply with Regulation (EU) 2017/745 (MDR) and achieve seamless market access in the European Union.

What is CE marking for medical devices?

CE marking is a mandatory certification confirming that a medical device meets EU safety, performance and regulatory requirements under MDR. It allows free movement of medical devices within the EEA and is a prerequisite for selling devices in the EU.

  • Confirms compliance with MDR 2017/745
  • Required for all medical devices (Class I, IIa, IIb, III)
  • Demonstrates product safety, quality and regulatory conformity
  • Mandatory for market entry in the EU

Our CE marking consultancy services

Device classification and regulatory strategy

  • Identifying the correct MDR classification (Class I, IIa, IIb, III)
  • Determining the appropriate conformity assessment route

Technical documentation preparation and review

  • Ensuring compliance with Annex II and III of MDR
  • Preparing the Device Technical File and Design Dossier
  • Assisting with Clinical Evaluation Reports (CER)

EU Authorised Representative services

  • Acting as your official EU Representative for regulatory compliance
  • Managing EUDAMED registration and post-market surveillance (PMS)

Notified Body interaction and certification support

  • Assisting in selecting a Notified Body (Class IIa, IIb, III devices)
  • Supporting the conformity assessment and audit process

Risk management and post-market surveillance

  • Implementing ISO 14971:2019 risk management requirements
  • Developing PMS and vigilance plans

CE marking training and compliance consulting

  • Expert training and workshops on MDR requirements

The CE marking process under MDR 2017/745

The steps are the same for every device, but the Notified Body involvement and the conformity assessment route depend on the class. Find your class in the top row and read down.

StepClass Inon-sterile, non-measuringClass Is / Im / Irsterile, measuring, reusable surgicalClass IIaClass IIbClass IIIall active implantables
1. ClassificationDetermine the class using Annex VIII of the MDR●Required●Required●Required●Required●Required
2. Quality management systemImplement a QMS in accordance with MDR; most companies apply ISO 13485●Required●Required●Required●Required●Required
3. Technical fileTechnical documentation per Annex II and III, including clinical evaluation●Required●Required●Required●RequiredRequired; clinical investigation data is likely to be needed
4. Authorised RepresentativeNon-EU manufacturers appoint an EC REP; name and address go on the packaging●Required●Required●Required●Required●Required
5. EUDAMED registrationRegister manufacturer and device; assign the UDI●Required●Required●Required●Required●Required
6. Notified Body audit of the QMSAudit by an EU-designated Notified BodyNot requiredLimited to the sterile, measuring or reuse aspects●Required●Required●Required
7. Notified Body review of the technical fileTechnical documentation or design dossier assessmentNot requiredLimited to the same aspectsSampled: one representative device per device categorySampled: one per generic device group; every device for most implantablesEvery device
8. CE certificateIssued by the Notified Body after a successful auditNot required●Required●Required●Required●Required
9. Declaration of Conformity and CE markingLegally binding declaration by the manufacturerSelf-declared; CE mark without Notified Body numberCE mark with Notified Body numberCE mark with Notified Body numberCE mark with Notified Body numberCE mark with Notified Body number
10. Post-market surveillanceOngoing reporting after market placementPMS reportPMS reportPSUR at least every two yearsPSUR every yearPSUR every year; SSCP

● Required for this class Not required Step does not apply

  • Class III devices and active implantable devices will likely require substantial clinical data. Clinical investigations conducted in Europe must be pre-approved by a Competent Authority. Existing clinical data may be acceptable. All data are reviewed by a Notified Body.
  • A Notified Body is an EU-designated third party authorised to audit medical device companies and their devices.
  • A CE certificate issued by a Notified Body does not apply to Class I non-sterile, non-measuring devices: the manufacturer self-declares conformity with Regulation (EU) 2017/745.

Conformity assessment route by class (MDR Article 52)

ClassRouteNotified Body
Class IDeclaration of Conformity based on the technical documentation of Annex II and III (Art. 52(7))None
Class Is / Im / IrAs Class I, plus Annex IX Chapters I and III or Annex XI Part A, limited to the sterile, measuring or reuse aspects (Art. 52(7))Limited scope
Class IIaAnnex IX Chapters I and III with assessment of the technical documentation of at least one representative device per device category; or Annex II and III documentation with Annex XI Section 10 or Section 18 (Art. 52(6))Yes
Class IIbAnnex IX Chapters I and III with assessment of the technical documentation of at least one representative device per generic device group; or Annex X type-examination with Annex XI (Art. 52(4))Yes
Class IIIAnnex IX with QMS audit and technical documentation assessment of every device; or Annex X type-examination with Annex XI Part A (Art. 52(3))Yes

This is a summary for orientation. The route for your device also depends on its classification rule and the special cases in Article 52. We confirm it with you during classification.

Who needs CE marking under MDR?

  • Medical device manufacturers (EU and non-EU)
  • Non-EU manufacturers, who must appoint an EU Authorised Representative
  • Distributors and importers, who must verify device compliance

Work flow for this service

Every engagement follows the same documented work flow (EUM-F-062), from your first enquiry to the closing review.

1Planning phase
  1. Client communication by e-mail, LinkedIn or through our collaborators
  2. Enquiry
  3. Application form shared and received (open the form)
  4. Contract review
  5. Quotation prepared and sent; revised or closed if not accepted
  6. Proforma invoice and draft agreement sent
  7. Payment received; invoice and final agreement sent
  8. Client coordination by e-mail and WhatsApp
2Execution phase
Consultancy: MDR | Regulation (EU) 2017/745

Our consultants prepare, review and deliver the agreed documents and systems.

EUDAMED registrationAuthorised representationTrainingAuditsConsultancy
3Reporting phase
  1. Internal feedback
  2. External feedback
  3. Complaint handling
  4. Non-conformity reporting
4Closing phase
  1. Review meeting
  2. Continuous improvement actions
  3. End of the engagement